Rslinx classic copy configure drivers
Rslinx classic copy configure drivers












rslinx classic copy configure drivers

NOTE: The PLC-5 can only hold one program at a time, and downloading to it will erase the PLC-5's currently loaded program. Step 14) Confirm you would like to download the current program you have open into the PLC-5 you are connected to:

rslinx classic copy configure drivers

Step 13) Then to download your program select the Download button: Step 12) In the popup Communications window expand your AB_DF1-1 driver and select your PLC-5: Step 11) Next, from the Comms menu select System Comms:

rslinx classic copy configure drivers

Step 10 Now open RSLogix 5, and then open your program file: Step 9) Next, double click on your new driver in the RSWho window and after a few seconds you should see your PLC-5 appear under the AB_DF1-1 driver as shown below: Step 8) And click on Close to close the Configure Drivers window: Step 7) Now click on OK to close the RS-232 DF1 Devices driver window: If your cables and PLC-5 are in working condition, and your PLC-5 is set to the default DF1 protocol, then you should see the message, “Auto Configuration Successful”: Step 5) Now select the COM port you looked up earlier, and check to be sure you have plugged your PLC-5 into it: Step 4) Accept the default name by clicking on OK: Step 3) Then from the Available Driver Types drop down list select RS-232 DF1 Devices and then click on Add New: Step 2) Next launch RSLinx Classic, and then under the Communications menu select Configure Drivers: Step 1) Start by checking Windows Device Manager to determine your PC's serial port COM number: Next, insure you have the RSLogix 5 programming software and either the 1784-CP10 or equivalent Null Modem Cable. If your PC does not have a built-in serial port you'll also need a USB to Serial converter. Note that the 9 Pin D Shell on the PLC-5/10, 5/12, 5/15, and 5/25 is not a serial port but instead internally tied to the DH+ terminal block. Prerequisites: Before you begin, first insure your PLC-5 has serial port (not all do.) So you need to know how to setup RSLinx Classic to communicate over serial with an Allen-Bradley PLC-5 so you can download or go online with RSLogix? Well you're in luck as in today's article I'll walk you step to setup through how to setup RSLinx as well as how to download from RSLogix:














Rslinx classic copy configure drivers